The 40 ton natural gas steam boiler is divided into a saturated steam boiler and a superheated steam boiler. It is a condensing double-drum vertical boiler, a double drum, a vertical type, and a D-type arrangement. The right side is a furnace, and the left side is a convection tube bundle. The convection tube bundle region is arranged; the movable support at the middle and both ends of the lower drum is fixed on the chassis of the body, and the whole boiler is expanded to both ends.
Rated evaporation: 40t/h
Rated steam pressure: 3.82MPa
Rated steam temperature: 350 °C
Feed water temperature: 104 °C
Boiler design thermal efficiency: 96.4%
Exhaust gas temperature: <100 °C
Combustion method: room combustion
Combustion adjustment mode: electronically controlled operation cabinet automatically adjusts
Natural gas consumption: 3320Nm3/h
Boiler body: 11560*4850*5500mm
Factory mode: bulk factory
Weight: 65t
Conditions of use: interior layout (open boiler room)
Ambient temperature: -12 ~ 45 °C
Adapt to seismic intensity: ≤7 degrees
Rated evaporation: 40t/h
Boiler outlet steam pressure: 3.82 MPa
Boiler outlet steam temperature: 430 °C (+15 °C, -5 °C) (when the fuel is natural gas, and the boiler operating load is ≥ 70% of the rated load of the boiler)
Design cold air temperature: normal temperature
Exhaust gas temperature: no more than 163 °C
Fuel type: natural gas, by-product fuel gas (mixed gas), alternately use boiler heat efficiency according to fuel low heat value: ≥91.0% boiler load automatic adjustment range: 20-110%
Boiler feed water temperature: 104 °C
Feed water pressure: 1.25Mpa ~ 6.0MPa
Weight: 75t